PRODUCTS

Air Treatment Systems

Daikin’s Outside Air Processing Unit can be integrated with a VRV system to provide outside air treatment and air conditioning in a single system to meet code requirements.

Creating a better air quality environment

These units adjust the temperature of air from outdoors using a fixed discharge temperature control reducing air conditioning load. In addition to Outside Air Processing Units, we also offer Energy Heat Recovery units.

The Energy Heat Recovery VAM-GVJU series units combines compactness, energy conservation, and extensive operation range of outdoor temperatures. This series provides higher enthalpy efficiency, due to the greatly enhanced performance of the thin heat exchanging element. Furthermore, improved external static pressure offers more flexibility for installation.

Select your Ventilation Solution:
Energy Recovery Ventilator
Energy Recovery Ventilator
100% Outside Air Processing Units
100% Outside Air Processing Units
Helping to Improve Indoor Air Quality and Energy Efficiency

Energy Recovery Ventilator

Energy Recovery Ventilator

This product is designed to maintain good indoor air quality by providing sufficient levels of fresh outside air and recover waste heat from extracted air leaving the conditioned zone. This new ERV unit is fully compatible with Daikin’s DIII-NET communications.

Click here to view the available accessories/controllers

Helping to Improve Indoor Air Quality and Energy Efficiency

100% Outside Air Processing Units

100% Outside Air Processing Units
Both fresh air treatment and heating and cooling can be achieved successfully in a single system via heat pump technology without the usual design problems associated with balancing air supply and discharge. Fan coil units and outdoor air processing unit can be connected to the same refrigerant line, resulting in enhanced design flexibility and a significant reduction in total system costs.

Energy

Recovery Ventilator

The Energy Heat Recovery VAM-GVJU series units combine compactness, energy conservation, and extensive operation range of outdoor temperatures.
Overview
Features
Resources

This product is designed to maintain good indoor air quality by providing sufficient levels of fresh outside air and recover waste heat from extracted air leaving the conditioned zone. This new ERV unit is fully compatible with Daikin’s DIII-NET communications.

Click here to view the available accessories/controllers

Features

• Provides energy-saving heat recovery ventilation via a new heat exchanger with high temperature and enthalpy recovery efficiency
• Design flexibility thanks to high static pressure fans and the capability for use in a wide range of climates (5°F to 122°F DB and 80% RH or less)*
• Wide range of functions such as independent operation, interlock with other HVAC systems and automatic night purge to reduce cooling loads and increase energy savings
• Interlocked simultaneous operation with VRV indoor units through a single controller
• Auto mode switches the ventilation mode (total heat exchange mode to bypass mode) according to the operating status of air conditioner system
• Pre-cooling/heating control function to delay the start of ventilation during air conditioner start-up for higher energy savings
• Supply and exhaust fresh-up operation modes to control pressure within a space
• Filter sign and display reset notifies when filter changes are required
• ESP as high as 0.76” W.G.
• Sound levels as low as 25.5 dB(A) for sound sensitive installation locations

* Note: Certified in accordance with the AHRI ERV Certification Program, which is based on AHRI Standard 1060. Certified units may be found in the AHRI Directory at www.ahridirectory.org. Performance characteristics certified to AHRI Standard 1060 based on the following conditions:

  • The cooling effectiveness shall be based on 95°F DB / 78°F WB for the entering supply air and 75°F DB / 63°F WB for the entering exhaust air, at a leaving supply airflow of both 100% and 75% of the rated airflow.
  • The heating effectiveness shall be based on 35°F DB / 33°F WB for the entering supply air and 70°F DB / 58°F WB for the entering exhaust air, at a leaving supply airflow of both 100% and 75% of the rated airflow.

Expand possibilities with connectivity

VRV EMERION offers connectivity to an ever-expanding offering of controls, ventilation, and indoor units.

Solution Builder

Customize your indoor comfort solution.

solution-builder-image

Butterfly icon banner

Enter your preferences, system criteria, and square footage to receive personalized recommendations for Daikin systems that best fit your needs.