![](/images/default-source/1-year-warranty/vam-gvju2.jpg)
![](/images/default-source/1-year-warranty/vam-gvju2.jpg)
Energy
Recovery Ventilator
This product is designed to maintain good indoor air quality by providing sufficient levels of fresh outside air and recover waste heat from extracted air leaving the conditioned zone. This new ERV unit is fully compatible with Daikin’s DIII-NET communications.
Click here to view the available accessories/controllers
Features
• Provides energy-saving heat recovery ventilation via a new heat exchanger with high temperature and enthalpy recovery efficiency
• Design flexibility thanks to high static pressure fans and the capability for use in a wide range of climates (5°F to 122°F DB and 80% RH or less)*
• Wide range of functions such as independent operation, interlock with other HVAC systems and automatic night purge to reduce cooling loads and increase energy savings
• Interlocked simultaneous operation with VRV indoor units through a single controller
• Auto mode switches the ventilation mode (total heat exchange mode to bypass mode) according to the operating status of air conditioner system
• Pre-cooling/heating control function to delay the start of ventilation during air conditioner start-up for higher energy savings
• Supply and exhaust fresh-up operation modes to control pressure within a space
• Filter sign and display reset notifies when filter changes are required
• ESP as high as 0.76” W.G.
• Sound levels as low as 25.5 dB(A) for sound sensitive installation locations
* Note: Certified in accordance with the AHRI ERV Certification Program, which is based on AHRI Standard 1060. Certified units may be found in the AHRI Directory at www.ahridirectory.org. Performance characteristics certified to AHRI Standard 1060 based on the following conditions:
- The cooling effectiveness shall be based on 95°F DB / 78°F WB for the entering supply air and 75°F DB / 63°F WB for the entering exhaust air, at a leaving supply airflow of both 100% and 75% of the rated airflow.
- The heating effectiveness shall be based on 35°F DB / 33°F WB for the entering supply air and 70°F DB / 58°F WB for the entering exhaust air, at a leaving supply airflow of both 100% and 75% of the rated airflow.
Warranty Certificate
Warranty Certificate - wc-pwdvrvseog-fr Warranty Certificate - wc-pwdvrvseomSubmittal Data
Submittal Data - sds-vam1200gvju Submittal Data - sds-vam300gvju Submittal Data - sds-vam470gvju Submittal Data - sds-vam600gvjuProduct Flyer
Product Flyer - pf-vam_gvjuProduct Brochure
Product Brochure - pb-cb-vrvt_04-24Installation Manual
Installation Manual - im-vam300-1200gvjuOperation Manual
Operation Manual - om-vam300-1200gvjuWritten Guide Spec
Written Guide Spec - wgs-vam_gvju-20211Engineering Manual
Engineering Manual - em-vam_gvju-(edus711116b)-01-04-2020Service Manual
Service Manual - sm-vam300-1200gvjuCAD Drawing
CAD Drawing - cad-vam1200gvju CAD Drawing - cad-vam300gvju CAD Drawing - cad-vam470gvjuRevit Drawing
Revit Drawing - rvt-vam300-1200gvjuExpand possibilities with connectivity
VRV EMERION offers connectivity to an ever-expanding offering of controls, ventilation, and indoor units.
![](/images/default-source/products/vrv/vrv-connectivity.png)